SHOTS - ENVIRONMENTAL ENGINEERING
💥 Use of metering system causes the decrease in per capita consumption.
💥 1.5 is the hourly factor, 1.8 daily factor and 2.7 is the peak demand.
💥 The distribution mains are designed for maximum hourly demand.
💥 Geometrical method is used for young and rapidly developed cities for forecasting the population.
💥 Arithmetical method is used for large cities.
💥 As compared to geometrical method arithmetical method gives less value.
💥 Intakes are installed for drawing the water from the sources.
💥 Reflux valve provided on the suction pipe in a tube well.
💥 The maximum discharge in tube well is 50lit/sec.
💥 As compare to the shallow wells deep wells have more discharge.
💥 Ground water is generally free from suspended impurities.
💥 Malaria is not a water borne disease.
💥 The most common cause of acidity in water is co2.
💥 The phenol compounds in water supply not more than 0.001ppm.
💥 1.5mg/litre is the permissible limit of fluoride content.
💥 Standard EDTA test is used to test the hardness of water.
💥 Alkalinity in water is expressed in calcium carbonate.
💥 Turbidity is measured on standard silica scale.
💥 Color on platinum cobalt scale.
💥 The turbidity of drinking water should be 10ppm.
💥 Residual chlorine is tested by starch iodide and orthotolidine method.
💥 Total solids not more than 500ppm.
💥 Total chlorides not more than 250ppm.
💥 Iron and magnesia 0.3ppm.
💥 Lead and arsenic 0.05ppm
💥 Copper 3ppm, fluorine 1.5ppm.
💥 The dissolved oxygen in natural unpolluted water is 10mg/litre.
💥 The length of the sedimentation tank should not be not more than 4 times the width.
💥 The over flow rate of plain sedimentation tank is 500 - 750litre/hr/m^2.
💥 The settling velocity of a particle depends upon surface area of tank.
💥 Efficiency of the sedimentation tank depends upon surface area of the tank.
💥 For effective coagulation the PH value of water found to be 6 - 8.5.
💥 The detention period of coagulation tank is 2 – 6 hour.
💥 The alum when added as coagulant it decreases the PH value of water.
💥 Lime is used to increase the speed of the sedimentation sewage.
💥 Air binding phenomena in rapid sand filters occurs due to excessive negative head.
💥 Backwashing provided in rapid sand filters.
💥 2 - 3 months is the period of cleaning of slow sand filter.
💥 Time contact of chlorine is at least 30min.
💥 The percentage of chlorine in fresh bleaching powder is 30 to 35%.
💥 The treatment of water with bleaching powder is called hypo chlorination.
💥 The suitable method of disinfecting the swimming pool water is ultraviolet rays treatment.
💥 Sulphur dioxide used for dechlorination of water.
💥 Disinfection efficiency reduced at higher PH values.
💥 Copper sulphate is used for algae control.
💥 Activated carbon is used for removing odours.
💥 Dead end system is used for irregularly growing towns.
💥 Radial system is used when the water is flowed towards the outer periphery.
💥 Grid iron system is used for well planned cities.
💥 Circle method is used when fire demand is considered.
💥 Sluice valve provided to regulate the flow of water.
💥 Reflux valve provided to prevent the water flow back in the opposite direction.
💥 Scour valves are provided at every depression head and dead ends.
💥 House sewer - lateral sewer - common sewer - main sewer - trunk sewer - outfall sewer.
💥 For country like India where rainfall is mainly confined to one season separate system is adopted.
💥 Combined system adopted when the rainfall is distributed throughout the season.
💥 135 litres domestic consumption.
💥 Sewerage system is generally designed for 25 years.
💥 For long and narrow pipe system equivalent pipe method is used.
💥 Circular shape sewer is preferred in separate system.
💥 Egg shape sewer is preferred in combined system.
💥 The time of concentration –the time taken by rainfall to run from most farthest point to the point of disposal.
💥 1 to 1.2m/sec is the self cleansing velocity of sewer in Indian condition.
💥 The slope of sewer should be in the direction of natural slope of ground.
💥 6*DWF for separate system.
💥 Rainfall+2DWF for combined system.
💥 15cm &300cm is the minimum and maximum diameter of sewer.
💥 The velocity of flow does not depend on length of sewer.
💥 Circular brick sewer is used under culverts.
💥 Egg shaped sewer is suitable for both separate and combined system.
💥 The characteristic of fresh and septic sewage is alkaline and acidic.
💥 The pathogens likely killed by chlorination.
💥 Standard BOD is measured at 5 day 20 degree.
💥 TOD>COD>BOD.
💥 5 day BOD is less than 4 day BOD.
💥 The ratio of 5 day BOD to ultimate BOD is 2/3.
💥 4ppm is the minimum DO to avoid the fish kill.
💥 Dissolved oxygen in streams is maximum at noon.
💥 The means of access for inspection and cleaning of sewer is manhole.
💥 Sewerage system is designed for maximum and minimum flow.
💥 Sewage treatment plant designed for average flow only.
💥 Laying of sewers is usually done with the help of boning rods and sight rails.
💥 In sewage oil and grease removed by skimming tank.
💥 Detention period of grit chamber is 1 minute.
💥 Sludge digestion tank and septic tank unit works on anaerobic condition.
💥 The maximum efficiency of BOD removal is achieved in oxidation ditch.
💥 The working condition of imhoff tanks are anaerobic in lower compartment and aerobic in upper compartment.
💥 The detention period of oxidation pond is 10 to 15 days.
💥 Compositing and lagoning are the methods of sludge disposal.
💥 Facultative bacteria works with or without oxygen.
💥 For satisfactory working of sludge digestion tank the PH value of water is 6 - 8.5.
💥 Normal value of sludge index is 150 - 350.
💥 Bangalore method practise anaerobic method of disposal.
💥 Antisiphonage pipe is used to preserve the water seal traps.
💥 In two pipe system one soil pipe, one waste pipe and two vent pipes required.
💥 The gas from sludge digestion tank mainly composed of methane.
💥 Most of the bacteria in sewage are saprophytic.
💥 Chlorine is used to separate grease.
💥 Shrouding is provided in slotted pipe tube well.
💥 Ozone layer in the outer atmosphere get destroyed by chlorofluoro carbons.
💥 The intensification of green house gases is due to CO2.
💥 Electrostatic precipitator is used to control particulate emission.
💥 Spray tower is used to control both gaseous and particulate pollutant.
💥 PAN and ozone are the secondary air pollutants.
💥 Sulphur dioxide and nitrogen oxide are the primary air pollutant.
💥 The depletion of ozone layer in the outer atmosphere causes the skin cancer.
💥 The acid rains are caused due to SO2 and NOx.
💥 Blue baby disease caused due to excess of nitrates.
💥 Dechlorination of water is achieved by sodium thio sulphate.
💥 The efficiency sedimentation tank does not depend upon depth of the tank.
💥 Sewage sickness caused due to clogging of pores in soil due to excessive application of sewage to land.
💥 Soil pipe carry human excrete.
💥 Screening - grit removal - primary sedimentation - aeration - secondary sedimentation.
💥 Traps are used to prevent the entry of foul smelling gases.
💥 Coal based thermal power stations produce SO2,NOx and SPM.
💥 Zone of degradation - zone of active decomposition - zone recovery - zone of clear water.
💥 River water contain maximum amount of turbidity.
💥 Ringle man scale is used to measure grade density of smoke.
💥 Eutrophication of water is rich in nutrients.
💥 Zero hardness is achieved by ion exchange method.
💥 Excess lead causes anaemia, goitre caused due to absence of iodide.
💥 Aerosol is dispersion of small solid or liquid droplet.
💥 A commonly used hand pipe is reciprocating pump.
💥 1 st stage is carbonaceous demand 2nd stage is nitrification demand.
💥 P trap used for water closet.
💥 The sound level of jet air plane is 140 decibel.
Comments
Post a Comment